Downloads products software usb drivers cs1w cif31

Dating > Downloads products software usb drivers cs1w cif31

Download links:Downloads products software usb drivers cs1w cif31Downloads products software usb drivers cs1w cif31

Note The USB-Serial Conversion Cables are compatible with Windows Vista. The cable can be used once the required drivers on the provided CD-ROM have been installed in the personal computer. Nevertheless, OMRON assumes no responsibility for errors or omissions. Click the Driver tab in the Network Settings dialog box. Connecting Online from the CX-Programmer tells how to connect to a PLC or PT from a computer running the CX-Programmer.

W417-E1-03 USB-Serial Conversion Cable User's Manual USB-Serial Conversion Cable CS1W-CIF31 User's Manual Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. OMRON Product References All OMRON products are capitalized in this manual. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. Indicates lists of one sort or another, such as procedures, checklists, etc. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. The CS1W-CIF31 USB-Serial Conversion Cable connects an OMRON PLC or PT to a personal computer's USB port. Please read this manual carefully and be sure you understand the information provided before attempting to install or operate the USB-Serial Conversion Cables. Be sure to read the precautions provided in the following section. Precautions provides general precautions for using the USB-Serial Conversion Cables and related devices. Overview and Components describes the parts of the USB-Serial Conversion Cables and gives an overview of their application. Packing Lists shows the various items that come with the USB-Serial Conversion Cables. Specifications provides the hardware and software specifications. Dimensions shows external cable dimensions. System Configuration shows the application of the USB-Serial Conversion Cables with various models of PLC. Application Procedure gives an overview of the steps required to use USB-Serial Conversion Cables. DIP Switch Settings and Cable Connections describes switch settings and cable connections. Installing the Drivers tells how to install the software drivers. Uninstalling the Drivers tells how to uninstall the software drivers. Connecting Online from the CX-Programmer tells how to connect to a PLC or PT from a computer running the CX-Programmer. WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. The information contained in this section is important for the safe and reliable application of the USB-Serial Conversion Cable. You must read this section and understand the information contained before attempting to set up or operate a USB-Serial Conversion Cable and PLC system. Be sure to read this manual before attempting to use the Conversion Cable and keep this manual close at hand for reference during operation. WARNING It is extremely important that a PLC and all PLC Units be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a PLC system to the above mentioned applications. Do not use them to connect any other devices and do not use a commercially available USB-serial conversion cable in place of these cables. Improper usage of these cables may result in damage to external devices, the PLC, or the PT. Doing so may cause the computer to malfunction. This is not a malfunction. The cable may malfunction. The cable may malfunction. The cable may malfunction. Caution 6 Perform wiring so that the power supply wires are not exposed and do not come into contact with any metal parts. Contact with metal parts may cause a fire. The actual products have been checked for conformity to EMC standards see the following note. Whether the products conform to the standards in the system used by the customer, however, must be checked by the customer. EMC-related performance of the OMRON devices that comply with EC Directives will vary depending on the configuration, wiring, and other conditions of the equipment or control panel on which the OMRON devices are installed. The customer must, therefore, perform the final check to confirm that devices and the overall machine conform to EMC standards. Note: Within the EMC Electromagnetic Compatibility standards, the applicable EMS Electromagnetic Susceptibility standard is EN61000-6-2 and the applicable EMI Electromagnetic Interference standard is EN61000-6-4 10-m regulations. Observe the following precautions to ensure that the machine or device in which the Conversion Cable is used complies with EC directives: 1. The CS1W-CIF31 USB-Serial Conversion Cable must be installed within a control panel. CS1W-CIF31 USB-Serial Conversion Cables complying with EC Directives also conform to the Common Emission Standard EN61000-6-4. Radiated emission characteristics 10-m regulations may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other conditions. You must therefore confirm that the overall machine or equipment complies with EC Directives. The cable can be used once the required drivers on the provided CD-ROM have been installed in the personal computer. Data is not being sent from the USB-Serial Conversion Cable. The USB-Serial Conversion Cable is receiving data. The USB-Serial Conversion Cable is not receiving data. The following software applications use CX-Server or FinsGateway. Name CX-Programmer CX-Simulator CX-Protocol CX-Position CX-Motion CX-Process NS-Designer PLC Reporter Communications software CX-Server FinsGateway is used for network communications. FinsGateway CX-Server FinsGateway is used for network communications. FinsGateway CX-Server FinsGateway or CX-Server FinsGateway FinsGateway The following software applications are also compatible. Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft Windows Device Manager see note 1 and specify that port in the NT Support Tool's communications settings. Once the communications port is specified correctly in the Windows Device Manager and the NT Support Tool's communications settings, data such as screen data can be downloaded to the PT or uploaded from the PT through the USB-Serial Conversion Cable. Note: In most personal computers, COM1 is allocated to the RS-232C port and communications port COM2 can be allocated to the Conversion Cable. Refer to Changing the Allocated Communications Port on page 36 for details on changing the communications port. Furthermore, if there is another driver using the allocated port, that driver must be uninstalled. Check the NT Support Tool's communications settings and verify that the communications port allocated to the Conversion Cable is also specified in the NT Support Tool. Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft Windows Device Manager see note 1 and specify that port in the NT Support Tool's communications settings. Once the communications port is specified correctly in the Windows Device Manager and the NT Support Tool's communications settings, the system program can be downloaded to the PT through the USB-Serial Conversion Cable. Note: In most personal computers, COM1 is allocated to the RS-232C port and communications port COM2 can be allocated to the Conversion Cable. Refer to Changing the Allocated Communications Port on page 36 for details on changing the communications port. Furthermore, if there is another driver using the allocated port, that driver must be uninstalled. Compatible PLCs, PTs and Programmable Relay The following OMRON PLCs, PTs and Programmable Relay are supported by the compatible software applications. The ZEN Programmable Relay is supported only if ZEN Support Software Ver. In particular, the CS1W-CIF31 Cable can be used only with compatible OMRON software applications even though it has a standard D-sub 9-pin connector on one end. Specifications General Specifications USB Interface rating DTE speed Connector specifications Computer end PLC end Power supply Current consumption Operating Ambient temperature environment Ambient humidity Atmosphere Weight Conforms to USB Specification 1. Host link SYSWAY Note: The host link mode can be used in all of these PLCs, but the peripheral bus mode cannot be th used in PLCs that have a 9 as the 4 digit of the lot number. The lot number may be 4 or 5 digits long. The lot number may be 4 or 5 digits long. Note 2: Only host link mode can be used. The C200H-LK201-V1 and C120-LK201-V1 Host Link Units can be used with the C200H. Use the procedure below when connecting a PLC CPU Unit and personal computer. The Conversion Cable uses one of the computer's COM ports for communications. When communicating with a PLC through a Conversion Cable, set the communications port COM port number used by the software to the communications port COM port number allocated to the Conversion Cable. Connect the Cable s. Connect the Conversion Cable to the computer's USB port and the CPU Unit's peripheral port or RS-232C port. For details, refer to Connecting the Cable on page 28. Install the communications driver. The Conversion Cable's communications driver must be installed in the computer in order for the computer to use the Conversion Cable. For details, refer to Installing the Driver on page 29. Turn ON the PLC's power. Turn ON the PLC's power supply. Make an online connection to the CPU Unit through the computer software when using the CX-Programmer. Select the COM port in the CPU Unit from the CX-Programmer and connect online. For details, refer to Connecting Online from the CX-Programmer on page 34. When more than one Conversion Cable is being used, connect the second and later Cables after the first Cable has been connected. The communications driver is automatically installed for the second and later Cables, so it is not necessary to install the driver a second time. Each Cable must have its own unique COM port number. Allocate a different COM port to each Cable. At this point, the driver can be installed with the wizard. The actual driver installation method depends on the OS being used. Windows 2000 is used in the examples in this section. Note The USB-Serial Conversion Cables are compatible with Windows XP. When you install the Conversion Cable's driver, a warning message will appear indicating that the driver software has not passed Windows Logo testing, but click Continue Anyway to proceed with the installation. We have thoroughly tested the driver on Windows XP and verified the it operates properly. The driver will not be installed properly if the installation process is cancelled before completion. Normal communications may not be possible if the driver is not installed properly. If the driver is not installed properly, uninstall it refer to page 33 and then reinstall it correctly. Note The USB-Serial Conversion Cables are compatible with Windows Vista. We have thoroughly tested the driver on Windows Vista and verified that it operates properly. The driver will not be installed properly if the installation process is cancelled before completion. Normal communications may not be possible if the driver is not installed properly. If the driver is not installed properly, uninstall it refer to page 33 and then reinstall it correctly. The following window will be displayed. The following window will be displayed. Click the Next button. The following window will be displayed. Select Search for a suitable driver for my device recommended and click the Next button. The following window will be displayed. Select Specify a location and click the Next button. The following window will be displayed. Insert the CD-ROM containing the driver the CD-ROM is in the same package as the Conversion Cable into the computer's CD-ROM drive. Click the Browse button, select the ftdibus. The following window will be displayed. Click the Next button to start the installing the driver. The following window will be displayed if the driver was installed properly. Click the Finish button. When the Finish button is clicked in step 6, the following window will be displayed for installation of the USB Serial Port driver. Follow the same procedure in steps 1 through 7 to install the USB Serial Port driver. Driver installation is completed after installation of the USB Serial Port driver. Verify that the drivers were installed properly with the Windows Device Manager, as shown in the following diagram. To access the Device Manager, open the Control Panel, open the System folder, click the Hardware tab, and click the Device Manager button. Disconnect the Conversion Cable from the computer. Select OMRON USB-to-Serial Converter Drivers and click the Delete button. The following window will be displayed. Click the Continue button. When the drivers have been successfully deleted, the message Uninstall complete, press Finish to exit will be displayed. Click the Finish button. This completes the deletion uninstallation of the Conversion Cable's drivers. The communications port COM port allocated to the Conversion Cable must be selected with the CX-Programmer in order to connect online to a PLC or PT. Note: It may take some time for the computer to detect the cable after the cable is connected. This is not a malfunction. Display the Change PLC dialog box. Click the Settings button in the Network Type area. Select the desired type of network. The Network Settings dialog box will be displayed. Click the Driver tab in the Network Settings dialog box. Locate the Port Name setting and select the COM port being used by the Conversion Cable. Note If you fail to connect with this USB Cable, turn OFF auto baud rate detection if it is being used by your software. With the CX-Programmer, auto baud rate detection can be turned OFF by clearing the selection for it on the Network Settings dialog box. The actual verification procedure depends on the operating system. This example shows the procedure for Windows 2000. Open the Control Panel, open the System folder, and click the Hardware tab. Click the Device Manager button. A communications port name will appear in parentheses. This is the communications port being used by the Conversion Cable. The actual change procedure depends on the operating system. This example shows the procedure for Windows 2000. Note If the new COM port is being used by another driver, that driver must be uninstalled. Click the Port Settings tab. Click the Advanced button. The following window will be displayed. Select the new COM port number from the COM Port Number list. Click the OK button to change the COM port used by the Conversion Cable. If a second Conversion Cable is connected after the driver has been installed, driver installation will be requested again. Install the driver from the CD-ROM again. The following window will be displayed. Select Install from a list or specific location Advanced and click the Next button. W417-E1-03 Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code Date Revised content 01 February 2003 Original production 02 October 2006 Page 7: Changed EMI standard number of EC Directives. Page 30: Changed the reference directory for the driver file. Page 37: Add section on using more than one Conversion Cable. Page 29: Changed information on installing the drivers. W417-E1-03 Note: Specifications subject to change without notice Printed in Japan Comments.

Last updated